Reactive power compensation units are used for power systems using high-load loads, usually installed in electrical engineering or substation areas for industrial projects such as plants. , Factories, buildings, offices, apartment buildings, hospitals ...
The
capacitor bank has the effect of increasing the power factor (cosφ) by using a
compensating capacitor as a reactive power source.
The
prison consists of multiple parts, each of which is controlled by the
Contactor. The closing or opening of the Contactor will change the number of
capacitors operating in parallel. A power relay controlling the power factor of
the network will open and close the Contactor so that the power factor of the
whole network is replaced. team.
-
Cabinet is made from steel sheet, powder coated, 1mm - 2mm thick with IP 43
protection rating - IP 55
-
Offset power range: 50 kVAr - 1000 kVAr
-
The cabinet can be controlled by Automatic or Manual mode
-
Cabinets can use electrical resistance coils to reduce the starting current
when switching capacitor banks or using other equipment depending on customer
requirements.
-
Reactive power compensation units are used for power systems using high-load
loads, usually installed in electrical engineering or substation areas for
industrial projects such as plants. , Factories, buildings, offices, apartment
buildings, hospitals ...
+
3CE capacitor cabinets can be controlled manually or automatically.
+
Cabinets can use electrical resistance rolls to reduce harmonics or use other
equipment depending on the requirements of customers.
+ Cabinets are designed to drain heat well and have ventilation system cooling cabinets and drying resistance to reduce moisture in the cabinet.
No.
List of basic specifications
1
Standard IEC 60439-1, IEC 60529
2
rated voltages 220-230 / 380-415 VAC
3
cutting line 25kA - 100kA
4
frequency 50Hz
5
maximum currents 100A - 6300A
6
IP Protection Level IP 43 - IP 55
7
Maximum thermal expansion 50 ° C
8
Power compensation 50kVAr - 1000kVAr
9
Compensation Levels From 3 to 14 levels
10
Tile material imported to industry standards JIS G3302
(Japan),
En10142 (Europe) and ASTM A653 / A653-08 (USA)
11
Surface Galvanized or powder coated RAL 7032, RAL 7033 and other colors
according to customer requirements.
12
Structures - Cabinets are designed in chassis form. Tole thickness 2.0 - 3.0mm
-
The cabinet is made from 1.5 - 2.0mm thick steel plate
-
The details are made by automatic control system
High
precision CNC
13
Size - H (height): 1200-2200
-
W (wide): 600-1200
-
D (deep): 400-1250